• 11151 Amman, Jordan

Red Spot Standard

  • Ratings from 2 Amps to 1250 Amps
  • Fully complies with the requirements of BS88 Parts 1 & 2 and the associated IEC269
  • ASTA 20 certified performance to 80kA, generally at 660Vac
  • ASTA certified at 40kA up to 460Vdc
  • Suitable for use in motor circuits and have superior motor starting ability, the availability of extended motor range Fuse Links (gM) enhances this capability
  • Used to provide certified Type 2 co-ordination to IEC947 together with the contactors and overload relays
  • Approved by leading authorities, including Power Generation Companies and Ministry of Defence
Read More

Red Spot 400 Series Compact

  • Ratings from 2 Amps to 400 Amps
  • Fully complies with the requirements of BS88 Parts 1 & 2 and IEC269
  • ASTA 20 certified performance of up to 415/440Vac at 80kA
  • Excellent short circuit energy limitation
  • The compact design offers the user the advantage of reduced size and cost saving, whilst maintaining superior electrical and thermal performance, meets the demands of over 80% of the market
  • Suitable for use in motor circuits and have superior motor starting ability, the availability of extended motor range Fuse Links (gM) enhances this capability

 

Read More

SAFECLIP Low Voltage Industrial Fuse Links – Offset Blade Tag

  • Ratings from 2 Amps to 125 Amps
  • Fully complies with the requirements of BS88 Parts 1 or 6
  • ASTA 20 certified performance at 240/415/440 Vac 80kA
  • Low power loss values, well within the limits specified in BS88
  • Off-set blade tag type for clip-in mounting provides economies in size & installation time
  • Suitable for use in motor circuits and have superior motor starting ability, the availability of extended motor range Fuse Links (gM) enhances this capability
Read More

Low Voltage Industrial Fuse Links: CanadianStandard

  • Range of HRC Fuse Links designed, fully tested and CSA approved as meeting the requirements of C22.2 No. 106-M1992
  • HRCI Fuse Links provide both overload and over current protection
  • Used in a wide variety of applications
  • HRCI are fast acting and are ideally suited for use on feeder circuits and loads which are mainly resistive
  • HRCII are CSA certified for an interrupting duty of 200kA at 600 Volt a.c
  • Also conform to IEC 269 for use at 600 Volt a.c
  • Provide good all round general purpose characteristics, making them ideally suited for both overload and motor circuit protection

 

Read More

Gerapid High Speed DC Breake

Gerapid is a high speed DC circuit breaker, suitable for protection of mains and semiconductors in railway and industrial applications.

They are special single pole breaker for application in all fixed installations, e.g. as feeder-breakers in tractionary substations (underground, trams, local trains), in industrial plant protection (electrolysis plants, mines or steel mills) or in particular physics research, for protection of the superconductive coils in purpose-built accelerators.

A wide range of models facilitates rated currents up to 10.000A and rated voltages up to 3900V in accordance with IEC 947-2, EN 50123-2 and ANSI C37.14.

Main Features and Benefits:

  • Same dimensions from 2600A up to 8000A
  • Rated voltage 1000V up to 4000V
  • Housing and arc chute with insulating material, with compact dimensions.
  • 2-stage contact system for long life main-contacts
  • Solenoid drive with integrated control unit, short time operated
  • Electromagnetic trip drive operating independent on current direction, fi xed or adjustable settings
  • Available with integrated current measurement unit type SEL (optional up to 4000A)
Read More

Links Type ‘K’

  • For use in oil to protect distribution circuits
  • Suitable for fitting into HV ring main units designed to ESI 41:12
  • Current ranges available:
    • 100A to 140A at 7.2kV
    • 5A to 120A at 12kV
    • 25A to 100A at 15.5kV
    • 20A – 80A at 17.5 kV
    • 50A to 63A at 24kV
    • 10A – 40A at 25.8kV
  • Meets dimensional and performance requirements of BS 2692 & IEC282
  • ASTA and/or KEMA certified short circuit testing

 

Read More

Links Type ‘K’

  • For use in air on motor starting and general applications
  • Current ranges available:
    • 5A to 450A at 3.6kV
    • 50A to 350A at 7.2kV
    • 32a to 350A at 12kV
  • Meets dimensional and performance requirements of BS 2692 & IEC282
  • ASTA and/or KEMA certified short circuit testing
  • High current rating in single body dimensions
  • Low current and energy let-through under max fault conditions
  • Excellent performance under low over-current conditions
  • Ability to resist ageing under repeated starting conditions
Read More