Miniature Circuit Breakers: Series GT

The Series GT miniature circuit breakers have a calibration temperature of 40°C. This differentiates them from the other Series G (30°C).
Within this series the GT10 has a smaller short circuit capacity than the GT25.
Following add-on devices can be delivered with these products: Auxiliary contacts, undervoltage release (Tele U), shunt trip (Tele L), motor operator (Tele Mp) and panel board switch (PBS).
Accessories are available for the MCB’s within our Series GT.
See below the main features for this range.

Features / Producttypes GT10 GT25
Standards EN/IEC 60947-2
Short circuit breaking capacity (kA) (AC) 10-30 15-100
Tripping characteristics B, C, D
Thermal settings ln (A) 0,5-63
Rated voltage AC Un (V) 240/415
Minimum operating voltage U B min (V) 12
Selectivity class
Mechanical/electrical endurance 20000/10000
Tropicalisation acc.to EN/IEC 60068-2 95%RH at 55°C
Terminal capacity flexible/rigid cable (mm 2 ) 25-35
Poles 1
  2
  3
  4
Weight (g/pole) 120
CE-marking X
Auxiliary contacts yes
Tele U (Undervoltage release) yes
Tele L (Shunt Trip) yes
Tele MP (Motor Operator) yes
PBS (Panel board switch) yes
Busbar system pin (top/bottom) yes/yes
Busbar system fork (top/bottom) -/yes
Accessories yes
Read More

VBS-Busbar system : Insulated Busbars

  • Insulated busbar, pin type system
  • Pin type for 2P or 1PN and 3P systems
  • Easy to install
  • Flat design = gain of space in the enclosure
  • Easy to use : cutting instead of sawing
  • Clear visibility when connecting the power supply cables
  • Universal for all power supplies (2 x 230V, 3 x 230V and 3 x 400 V + N)
Read More

Residential Controls Devices – Add-On RCD’s

People protection against the risk of electrocution and property protection against the risk of an electrical fire.

  • In accordance with IEC 61009
  • Unique connection system provides optimum user safety
  • For use with 2P, 3P & 4P MCB’s up to 63A (up to 125A using HTi MCB and HTi add-on RCD)
  • People protection against the risk of electrocution 10mA, 30mA and 100mA and above mainly protection against the risk of an electrical fire
  • 30mA, 100mA, 300mA, 500mA and 1000mA sensitivities
  • Available in type AC, A and S (Selective/Time delayed)
Read More

Tele REC: The Ultimate Reconnection System forRCCB’s

Ensures power continuity in critical applications.

The Tele REC relay automatically recloses the RCCB after an earth leakage or a manual disconnect. The relay will attempt to re-close 6 times with different time intervals between re-close attempts. After 6 unsuccessful attempts the Tele REC is locked.

Features

  • Status indicator: The yellow lever clearly indicates the status of the Tele REC. In position 1 the relay is ready to work, in position 0 the relay is blocked both electrically and mechanically.
  • Easy connection: The RCCB toggle slides easily into the toggle actuator of the relay.
  • Part of the family: For each series of RCCB’s – ElfaPlus, Redline and DMS line – a specific Tele REC reconnector is available.
  • Auxiliary contact: Tele REC is equipped with an auxiliary contact (LI) to operate the re-closing system from a push-button.
  • Stable and secure: Strong clips to ensure a stable connection between the RCCB and the Tele REC relay.
  • Full awareness: The relay is also equipped with a volt free output to indicate the status of the protection (connected/ disconnected).
  • One fits all: Both 2 modules and 4 modules RCCB’s can be connected to the reconnection relay Tele REC.

Complete range of reconnection relays

 

  • Tele REC DMS: Specially designed for the residential market.
  • Tele REC BASIC Type A and AC: For the residential/commercial markets. Commercial, banks, office buildings, hospitals,..
  • Tele REC BASIC Type Ai: Power maintenance and reliability in one device. Banks, hospitals, farms, public lighting, traffic lighting,…
  • Tele REC PLUS: For the commercial/industrial markets. The reconnection relay Tele REC Plus can be easily coupled to any ElfPlus RCCB.
  • Tele REC SOLAR: Specially designed for photovoltaic applications. The reconnection relay Tele REC SOLAR can be easily coupled to MCB’s series EP100 UC.

 

Read More

Residential Controls Devices -RCBO’s DME

Supplementary protection for people from the risk of electrocution and for property from the risk of an electrical fire. Overcurrent protection of equipment and cables.

  • Series DME

  • In accordance with IEC 61009
  • 6 and 10kA fault rating
  • Type AC or type A
  • Combines over current (MCB) and earth leakage (RCD) protection in one unit
  • People protection against the risk of electrocution 10mA, 30mA and 100mA and above mainly protection against the risk of an electrical fire
  • Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
  • Type B and C tripping characteristic
  • Flying neutral lead version for installing in consumer units, and distribution boards
  • Wire in/out (not shown) for OEM / separate enclosure installation
  • 2 Module RCBO 1P+N isolates both live and neutral
  • 1 Module RCBO offers space saving features and makes upgrading circuits easy
  • 1 Module RCBO includes earth reference cable to provide protection in case of loss of neutral
Read More

Residual Current Circuit Breakers – RCBO’s DPA100 UL approval

People protection against the risk of electrocution and property protection against the risk of an electrical fire. Also with overcurrent protection.

 

  • In accordance with EN/IEC 61009-1
  • Recognized UL 1053, UL file E248309
  • Maximum voltage AC (V) 240 or 277
  • Fault current withstand (kA) 5 (277V), 10 (240V)
  • Thermal settings In (A) 10-32
  • Residual current IΔ n (mA) 10, 30, 100, 300
  • Tripping characteristic B-C
  • Selectivity class 3
  • Rated maximum voltage AC Un (V) 240
  • Minimum operating voltage U bmin (V) 100
  • Nuisance tripping resistance  250A 8/20μs;
                                                   200A 0,5μs-100kHz
  • Making and breaking capacity (EN/IEC 61009-1) Im = 6000A
  • Residual making and breaking capacity (EN/IEC 61009-1) Icn = 5000/10000A at 230V
  • Short-circuit capacity (EN/IEC 60947-2) Icu = 15000A at 230V
  • CEBEC and UR approval
Read More

Residual Current Circuit Breakers – RCCB’sseries FPAUL UL approval

People protection against the risk of electrocution and property protection against the risk of an electrical fire.

 

  • In accordance with EN/IEC 61008-1
  • Recognized UL 1053, UL file E248309
  • Maximum voltage AC (V) 240
  • Fault current withstand (kA) 10
  • Thermal settings In (A) 16, 25, 40, 63
  • Residual current IΔ n (mA) 10, 30, 100, 300, 500
  • Rated maximum voltage AC Un (V) 2P: 240,4P: 240/415
  • Minimum operating voltage U bmin (V) 2P: 117, 4P: 190
  • Type A with 2 poles and 4 poles
  • Terminal capacity flexible/rigid cable (mm 2) 35-50
  • Nuisance tripping resistance Type A: 250A 8/20μs;                                                             3000A 8/20μs
  • Making and breaking capacity Im = 500A
  • Residual making and breaking capacity
                                            IΔm ≥ 500A from 16 up to 40A                                         IΔm  = 10In from 63 up to 100A
  • Short-circuit capacity Inc =
    10000A at 230/400V fuse 80A gG
  • UR approval
Read More

Residual Current Circuit Breakers – RCBO’sDM100

People protection against the risk of electrocution and property protection against the risk of an electrical fire.

  • Series DM100
  • In accordance with IEC 61009
  • 10kA fault rating
  • Supplementary protection for people (up to 10/30mA) and property (above 30mA)
  • Type AC or type A
  • Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
  • 10mA,30mA,100mA and 300mA sensitivity options
  • Type B and C tripping characteristics
  • 2Module, 1P+N isolates both live and neutral
  • Advanced design requires no earth lead
Read More